Transcat

Tektronix Encore




Agilent MSOX3052A, Keysight MSOX3052A, HP MSOX3052A
Oscilloscope, 500 MHz, 2 + 16 Chs., 4 GSa/s

Oscilloscopes >> Mixed Signal >> Oscilloscope, 500 MHz, 2 + 16 Chs., 4 GSa/s
Rent Used Test Equipment
Manufacturer: Keysight / Agilent / HP
Model: MSOX3052A

Keysight / Agilent MSOX3052A Oscilloscope, 500 MHz, 2 + 16 Chs., 4 GSa/s

Electronic Test and Measurement Equipment

Keysight / Agilent MSOX3052A Oscilloscope, 500 MHz, 2 + 16 Chs., 4 GSa/s Product Datasheet Download Product Datasheet

Rent Test Equipment

Product Overview

RENT KEYSIGHT MSOX3052A (Agilent) OSCILLOSCOPE (Call for Availability)

The Agilent MSOX3052A is a two-channel model in the InfiniiVision 3000 X-Series. Engineered with breakthrough technology this upgradable oscilloscope provides superior performance and functionality. Its unique 5-instruments-in-one design delivers more scope for the same budget.

Features and Specifications of the Keysight MSOX3052A Oscilloscope include:

Features of the Agilent MSOX3052A include:

  • One million waveforms per second update rate
  • MegaZoom IV smart memory technology
  • Large 8.5-inch WVGA display
  • Optional segmented memory
  • Industry's first 5-instruments-in-1:
    • Oscilloscope  
    • Digital channels
    • Built-in 20 MHz function/arbitrary waveform generator with modulation
    • Integrated digital voltmeter
    • Protocol analyzer
  • Investment protection with Industry's only fully-upgradable oscilloscope, including bandwidth up to 1 GHz
  • Industry's leading applications solution

Specifications of the Keysight MSOX3052A include:

  • Bandwidth (-3 dB):  500 MHz
  • Calculated rise time (10 - 90%):  ≤ 700 ps
  • Input channels:
    • 2 analog channels
    • 16 digital channels
  • Maximum sample rate:
    • 4 GSa/s half channel
    • 2 GSa/s all channel
  • Maximum memory depth:
    • Standard 2 Mpts
    • Optional 4 Mpts
    • Optional segment memory
  • Display size and type:  8.5 WVGA display
  • Waveform update rate:  > 1 million waveforms per second
  • Number of active probes supported:  In general, one for 2-channel models
  • Vertical system analog channels:
    • Hardware bandwidth limits:  Approximately 20 MHz (selectable)
    • Input coupling:  AC, DC
    • Input impedance:  Selectable:  
      • 1 MΩ ± 1% (14 pF)
      • 50 Ω ± 1.5%
    • Input sensitivity range:  1mV/div to 5 V/div (1 MΩ and 50 Ω)
    • Vertical resolution:  8 bits (measurement resolution is 12 bits with averaging)
    • Maximum input voltage:
      • 300 Vrms, 400 Vpk
      • Transient overvoltage 1.6 kVpk
      • With N2862A, N2863A, N2890A 10:1 probe: 300 Vrms
      • Frequency de-rating (assumes sine wave input): 400 Vpk until 40 kHz, then de-rates at 20 dB/dec until 6 Vpk
    • DC vertical accuracy:  ±[DC vertical gain accuracy + DC vertical offset accuracy + 0.25% full scale]
    • DC vertical gain accuracy: ± 2.0% full scale
    • DC vertical offset accuracy:  ± 0.1 div ± 2 mV ± 1% of offset setting
    • Channel-to-channel isolation:  > 100:1 from DC to maximum specified bandwidth of each model (measured with same V/div and coupling on channels)
    • Offset range:
      • ± 2 V (1 mV/div to 200 mV/div)
      • ± 50 V (> 200 mV/div to 5 mV/div)
  • Vertical system digital channels:
    • Digital input channels:  16 digital (D0 to D15. pod 1:D7 ~ D0, Pod 2: D15 ~ D8)
    • Thresholds: Threshold per pod
    • Threshold selections:  TTL (+1.4 V), 5V CMOS (+2.5 V), ECL (-1.3 V), user-defined (selectable by pod)
    • User-defined threshold range:  ± 8.0 V in 10 mV steps
    • Maximum input voltage:  ± 40 V peak CAT l; transient overvoltage 800 Vpk
    • Threshold accuracy:  ± (100 mV + 3% of threshold setting)
    • Maximum input dynamic range:  ± 10 V about threshold
    • Minimum voltage swing:  5 mVpp
    • Input impedance:  100 kΩ ± 2% at probe tip
    • Input capacitance:  ~8 pF
    • Vertical resolution: 1 bit
  • Horizontal system analog channels:  
    • Time base range:  1 ns/div to 50 s/div
    • Time base accuracy:  25 ppm ± 5 ppm per year (aging)
    • Time base delay time range:
      • Pre-trigger:  Greater of 1 screen width or 250 μs  
      • Post-trigger:  1 s to 500 s
    • Channel-to-channel deskew range:  ± 100 ns
    • Δ Time accuracy (using cursors):  ± (time base acc. x reading) ± (0.0016 x screen width) ± 100 ps
    • Modes:  Main, zoom, roll, XY
    • XY:
      • On channels 1 and 2 only, Z Blanking on ext trigger input, 1.4 V threshold  
      • Bandwidth:  Maximum bandwidth
      • Phase error at 1 MHz: < 0.5 degree
  • Horizontal system digital channels:  
    • Minimum detectable pulse width:  5 ns
    • Channel-to-channel skew:
      • 2 ns (typical)
      • 3 ns (maximum)
  • Aquisition system:
    • Maximum analog channels sample rate:  
      • 4 GSa/s half channel interleaved
      • 2 GSa/s all channel
    • Maximum analog channels record length:
      • 2 Mpts half channel interleaved, 1 Mpts all channel (standard)
      • 4 Mpts half channel interleaved, 2 Mpts all channel (optional with DSOX3MEMUP (-040))
    • Maximum duration of time captured at highest sampling rate (all analog channels):  500 us with 4M memory upgrade
    • Maximum digital channels sample rate:  1 GSa/s
    • Maximum digital channels record length:  
      • 1 Mpts (standard with digital channels only)
      • 2 Mpts (optional with DSOX3MEMUP - with digital channels only)
    • Modes:
      • Normal:  Default mode
      • Peak detect:  Capture glitches as narrow as 250 ps at all time base settings
      • Averaging:  Selectable from 2, 4, 8, 16, 64, ... to 65,536
      • High resolution:
        • Real time boxcar averaging reduces random noise and effectively increases vertical resolution
        • 12 bits of resolution when ≥ 10 μs/div at 4 GSa/s
        • or ≥ 20-μs/div at 2 GSa/s
      • Segmented:
        • Segmented memory optimizes available memory for data streams that have long dead times between activity
        • Maximum segments = 1000
        • Re-arm time = 1 μs (minimum time between trigger events)
  • Trigger system:
    • Trigger sources:  Analog channel  (1~4), digital channel (D0~D15), line, external, WaveGen (1 or mod) (FM/FSK)
    • Trigger modes:
      • Normal (triggered): requires trigger event for scope to trigger
      • Auto : triggers automatically in absence of trigger event
      • Single: triggers only once on a trigger event, press [Single] again for scope to find another trigger event, or press [Run] to trigger continuously in either Auto or Normal mode
      • Force:  front panel button that forces a trigger
    • Trigger coupling:  
      • DC: DC coupled trigger
      • AC: AC coupled trigger, cutoff frequency: < 10 Hz (internal);
      • High frequency reject:  cutoff frequency ~ 50 kHz
      • Low frequency reject:  cutoff frequncy ~ 50 kHz 
      • Noise reject:
        • Selectable OFF or ON
        • Decreases sensitivity 2x
    • Trigger holdoff range: 40 ns to 10.00 s  
    • Trigger sensitivity:
      • Internal: < 10 mV/div: greater of 1 div or 5 mV; ≥ 10 mV/div: 0.6 div
      • External:
        • 200 mVpp from DC to 100 MHz
        • 350 mVpp 100 MHz to 200 MHz
    • Trigger level range:
      • Any channel:  ± 6 div from center screen
      • External:  ± 8 V

 

Click to see all the models in this series

REQUEST A QUOTE




Testimonials

Great RF Test Equipment, in very good condition. I am very satisfied with the purchase and also with your management. It has been a pleasure to do business with you, and I hope to go on.


-- Jose




Why Choose Axiom?


Your testing is complicated enough, we want to make sourcing test equipment the easy part.


Dedicated Customer Service
We go beyond the role of order taker & strive to partner with you to provide a custom solution.
Competitive Prices
Equipment is agressively priced. We work with you to find a solution to fit your budget.

Fast Turnaround
No long drawn-out sales process, We help you find the equipment you need, and get through order processing quickly so your equipment ships out fast!

Warranty & Support
Comprehensive Parts and Labor warranty on all equipment sold. Includes a user manual, is fully accessorized, and tested to manufacturer specifications prior to shipment.

Testimonials

For the first time in a long time, can I just say thanks for the excellent unit you sold me even better than the one in the picture. Fantastic to deal with a honest human for a change.

Walter R.




Home   |   Rental Equipment   |   Equipment Sales   |   Repair   |   Calibration   |   Sell Equipment   |   About   |   Contact   |   Get A Quote   |   Blog  |   Videos

Subscribe to receive our weekly news & promotions
SUBSCRIBE




FAQ      Privacy      Terms      Site Map     


© 2024 Axiom Test, All Rights Reserved   

Axiom Test Equipment
2610 Commerce Way Vista, CA 92081
sales@axiomtest.com
(760) 806-6600