Tektronix Encore

Transcat




Agilent DSOX3102A, Keysight DSOX3102A, HP DSOX3102A
Oscilloscope 1 GHz, 2 Ch.

Oscilloscopes >> More than 500 MHz, up to 1 GHz >> Oscilloscope 1 GHz, 2 Ch.
Rent Used Test Equipment
Manufacturer: Keysight / Agilent / HP
Model: DSOX3102A

Keysight / Agilent DSOX3102A Oscilloscope 1 GHz, 2 Ch.

Electronic Test and Measurement Equipment

Keysight / Agilent DSOX3102A Oscilloscope 1 GHz, 2 Ch. Product Datasheet Download Product Datasheet

Rent Test Equipment

Product Overview

RENT KEYSIGHT DSOX3102A (AGILENT) OSCILLOSCOPE (Call for Availability)

The Keysight DSOX3102A (Agilent) is a two-channel model in the InfiniiVision 3000 X-Series. Engineered with breakthrough technology this upgradable oscilloscope provides superior performance and functionality. Its unique 5-instruments-in-one design delivers more scope for the same budget.

Features and Specifications of the Keysight DSOX3102A Oscilloscope include:

Features of the Agilent DSOX3102A include:

  • One million waveforms per second update rate
  • MegaZoom IV smart memory technology
  • Large 8.5-inch WVGA display
  • Optional segmented memory
  • Industry's first 5-instruments-in-1:
    • Oscilloscope  
    • Digital channels
    • Built-in 20 MHz function/arbitrary waveform generator with modulation
    • Integrated digital voltmeter
    • Protocol analyzer
  • Investment protection with Industry's only fully-upgradable oscilloscope, including bandwidth up to 1 GHz
  • Industry's leading applications solution

Specifications of the Keysight  DSOX3102A (Agilent) include:

  • Bandwidth (-3 dB):  1 GHz
  • Calculated rise time (10 - 90%):  ≤ 450 ps
  • Input channels:  2 analog channels
  • Maximum sample rate:
    • 5 GSa/s half channel
    • 2.5 GSa/s all channel
  • Maximum memory depth:
    • Standard 2 Mpts
    • Optional 4 Mpts
    • Optional segment memory
  • Display size and type:  8.5 WVGA display
  • Waveform update rate:  > 1 million waveforms per second
  • Number of active probes supported:  In general, one for 2-channel models
  • Vertical system analog channels:
    • Hardware bandwidth limits:  Approximately 20 MHz (selectable)
    • Input coupling:  AC, DC
    • Input impedance:  Selectable:  
      • 1 MΩ ± 1% (14 pF)
      • 50 Ω ± 1.5%
    • Input sensitivity range:  1mV/div to 5 V/div (1 MΩ and 50 Ω)
    • Vertical resolution:  8 bits (measurement resolution is 12 bits with averaging)
    • Maximum input voltage:
      • 300 Vrms, 400 Vpk
      • Transient overvoltage 1.6 kVpk
      • With N2862A, N2863A, N2890A 10:1 probe: 300 Vrms
      • Frequency de-rating (assumes sine wave input): 400 Vpk until 40 kHz, then de-rates at 20 dB/dec until 6 Vpk
    • DC vertical accuracy:  ±[DC vertical gain accuracy + DC vertical offset accuracy + 0.25% full scale]
    • DC vertical gain accuracy: ± 2.0% full scale
    • DC vertical offset accuracy:  ± 0.1 div ± 2 mV ± 1% of offset setting
    • Channel-to-channel isolation:  > 100:1 from DC to maximum specified bandwidth of each model (measured with same V/div and coupling on channels)
    • Offset range:
      • ± 2 V (1 mV/div to 200 mV/div)
      • ± 50 V (> 200 mV/div to 5 mV/div)
  • Vertical system digital channels:
    • Digital input channels:  16 digital (D0 to D15. pod 1:D7 ~ D0, Pod 2: D15 ~ D8)
    • Thresholds: Threshold per pod
    • Threshold selections:  TTL (+1.4 V), 5V CMOS (+2.5 V), ECL (-1.3 V), user-defined (selectable by pod)
    • User-defined threshold range:  ± 8.0 V in 10 mV steps
    • Maximum input voltage:  ± 40 V peak CAT l; transient overvoltage 800 Vpk
    • Threshold accuracy:  ± (100 mV + 3% of threshold setting)
    • Maximum input dynamic range:  ± 10 V about threshold
    • Minimum voltage swing:  5 mVpp
    • Input impedance:  100 kΩ ± 2% at probe tip
    • Input capacitance:  ~8 pF
    • Vertical resolution: 1 bit
  • Horizontal system analog channels:  
    • Time base range:  500 ps/div to 50 s/div
    • Time base accuracy:  25 ppm ± 5 ppm per year (aging)
    • Time base delay time range:
      • Pre-trigger:  Greater of 1 screen width or 250 μs  
      • Post-trigger:  1 s to 500 s
    • Channel-to-channel deskew range:  ± 100 ns
    • Δ Time accuracy (using cursors):  ± (time base acc. x reading) ± (0.0016 x screen width) ± 100 ps
    • Modes:  Main, zoom, roll, XY
    • XY:
      • On channels 1 and 2 only, Z Blanking on ext trigger input, 1.4 V threshold  
      • Bandwidth:  Maximum bandwidth
      • Phase error at 1 MHz: < 0.5 degree
  • Horizontal system digital channels:  
    • Minimum detectable pulse width:  5 ns
    • Channel-to-channel skew:
      • 2 ns (typical)
      • 3 ns (maximum)
  • Aquisition system:
    • Maximum analog channels sample rate:  
      • 5 GSa/s half channel interleaved
      • 2.5 GSa/s all channel
    • Maximum analog channels record length:
      • 2 Mpts half channel interleaved, 1 Mpts all channel (standard)
      • 4 Mpts half channel interleaved, 2 Mpts all channel (optional with DSOX3MEMUP (-040))
    • Maximum duration of time captured at highest sampling rate (all analog channels):  400 us with 4M memory upgrade
    • Maximum digital channels sample rate:  1.25 GSa/s
    • Maximum digital channels record length:  
      • 1 Mpts (standard with digital channels only)
      • 2 Mpts (optional with DSOX3MEMUP - with digital channels only)
    • Modes:
      • Normal:  Default mode
      • Peak detect:  Capture glitches as narrow as 250 ps at all time base settings
      • Averaging:  Selectable from 2, 4, 8, 16, 64, ... to 65,536
      • High resolution:
        • Real time boxcar averaging reduces random noise and effectively increases vertical resolution
        • 12 bits of resolution when ≥ 10 μs/div at 4 GSa/s
        • or ≥ 20-μs/div at 2 GSa/s
      • Segmented:
        • Segmented memory optimizes available memory for data streams that have long dead times between activity
        • Maximum segments = 1000
        • Re-arm time = 1 μs (minimum time between trigger events)
  • Trigger system:
    • Trigger sources:  Analog channel  (1~4), digital channel (D0~D15), line, external, WaveGen (1 or mod) (FM/FSK)
    • Trigger modes:
      • Normal (triggered): requires trigger event for scope to trigger
      • Auto : triggers automatically in absence of trigger event
      • Single: triggers only once on a trigger event, press [Single] again for scope to find another trigger event, or press [Run] to trigger continuously in either Auto or Normal mode
      • Force:  front panel button that forces a trigger
    • Trigger coupling:  
      • DC: DC coupled trigger
      • AC: AC coupled trigger, cutoff frequency: < 10 Hz (internal);
      • High frequency reject:  cutoff frequency ~ 50 kHz
      • Low frequency reject:  cutoff frequncy ~ 50 kHz 
      • Noise reject:
        • Selectable OFF or ON
        • Decreases sensitivity 2x
    • Trigger holdoff range: 40 ns to 10.00 s  
    • Trigger sensitivity:
      • Internal: < 10 mV/div: greater of 1 div or 5 mV; ≥ 10 mV/div: 0.6 div
      • External:
        • 200 mVpp from DC to 100 MHz
        • 350 mVpp 100 MHz to 200 MHz
    • Trigger level range:
      • Any channel:  ± 6 div from center screen
      • External:  ± 8 V

 

Click to see all the models in this series

REQUEST A QUOTE




Testimonials

I feel like I am getting the best service and the best pricing – the best of both worlds from Axiom.


-- Jon P.
San Diego, CA



Why Choose Axiom?


Your testing is complicated enough, we want to make sourcing test equipment the easy part.


Dedicated Customer Service
We go beyond the role of order taker & strive to partner with you to provide a custom solution.
Competitive Prices
Equipment is agressively priced. We work with you to find a solution to fit your budget.

Fast Turnaround
No long drawn-out sales process, We help you find the equipment you need, and get through order processing quickly so your equipment ships out fast!

Warranty & Support
Comprehensive Parts and Labor warranty on all equipment sold. Includes a user manual, is fully accessorized, and tested to manufacturer specifications prior to shipment.

Testimonials

Great RF Test Equipment, in very good condition. I am very satisfied with the purchase and also with your management. It has been a pleasure to do business with you, and I hope to go on.

Jose




Home   |   Rental Equipment   |   Equipment Sales   |   Repair   |   Calibration   |   Sell Equipment   |   About   |   Contact   |   Get A Quote   |   Blog  |   Videos

Subscribe to receive our weekly news & promotions
SUBSCRIBE




FAQ      Privacy      Terms      Site Map     


© 2024 Axiom Test, All Rights Reserved   

Axiom Test Equipment
2610 Commerce Way Vista, CA 92081
sales@axiomtest.com
(760) 806-6600