Keithley 2304A High Speed Precision Power Supply, 20V, 5A, 100W

Price: $1,385.00 (starting at)
See Configurations Below
Model: 2304A
Manufacturer: Keithley

 

Keithley 2304A High Speed Precision Power Supply, 20V, 5A, 100W
Click to enlarge

Request a Rapid Quote by Email

*Required

Available Option Configurations:
 Config-01
  • No Options Included
  Retail Price: $2,622.00 | Our Price: $1,385.00

The Keithley 2304A Power Supply provides both voltage control and power consumption monitoring for automated testing of portable, battery-operated devices. The Keithley 2304A Power Supply is optimized for testing battery-operated, wireless communication devices such as cellular phones that undergo substantial load changes for very short time intervals. The Keithley 2304A Power Supply exhibits outstanding voltage stability during pulse load changes and can simultaneously measure load currents, even if they are short pulses. In addition, the Keithley 2304A Power Supply can sink current and, thus, take on the characteristics of a discharged, rechargeable battery for testing chargers and charger-control circuitry.

Features and Specifications of the Keithley 2304A Power Supply include:

DC Voltage Output

  • Output Voltage:
    • 0 to +20VDC (for Normal Output Response)
    • 0 to +15VDC (for Enhanced Output Response)
  • Output Accuracy: ±(0.05% + 10mV)
  • Programming Resolution: 5mV
  • Readback Accuracy: ±(0.05% + 10mV)
  • Readback Resolution: 1mV
  • Output Voltage Settling Time: 5ms to within stated accuracy
  • Load Regulation: 0.01% + 2mV
  • Line Regulation: 0.5mV
  • Stability: 0.01% + 0.5mV
  • Transient Response to 1000% Load Change:
    • Normal Mode:
      • Transient Recovery Time:
        • <50µs to within 100mV of previous level
        • <100µs to within 20mV of previous level
    • Enhanced Mode:
      • Transient Recovery Time:
        • <40µs to within 100mV of previous level
        • <80µs to within 20mV of previous level
      • Transient Voltage Drop:
        • <100mV, typical
        • <200mV, typical
  • Remote Sense: Automatic, 2V max drop in each lead. Add 2mV to the voltage load regulation specification for each 1V change in the negative output lead due to load current change.

DC Current

  • Output Current: 5A max (not intended to be operated in parallel)
  • Compliance Accuracy: ±(0.16% + 5mA)
  • Programmed Compliance Resolution: 1.25mA
  • Readback Accuracy:
    • 5A range: ±(0.2% + 1mA)
    • 5mA range: ±(0.2% + 1µA)
  • Readback Resolution:
    • 5A range: 100µA
    • 5mA range: 0.1µA
  • Current Sink Capacity:
    • 3A max (for Normal Output Response)
    • 1A (for Enhanced Output Response)
  • Load Regulation: 0.01% + 1mA
  • Line Regulation: 0.5mA
  • Stability: 0.01% + 50µA

Digital Voltmeter Input

  • Input Voltage Range: 0 to +20VDC
  • Input Impedance: 10O typical
  • Maximum Voltage (either input terminal) With Respect to Output Low: –3V, +22V
  • Reading Accuracy: ±(0.05% + 10mV)
  • Reading Resolution: 1mV

DC General

  • Measurement Time Choices: 0.01 to 10 PLC, in 0.01PLC steps
  • Average Readings: 1 to 10
  • Reading Time 1: 31ms, typical

Pulse Current Measurement Operation

  • Trigger Level: 5mA to 5A, in 5mA steps
  • Trigger Delay: 0 to 100ms, in 10µs steps
  • Internal Trigger Delay: 25µs
  • High/Low Average Mode:
    • Measurement Aperture Settings: 33.3µs to 833ms, in 33.3µs steps
    • Average Readings: 1 to 100
  • Burst Mode:
    • Measurement Aperture: 33.3µs
    • Conversion Rate: 3600/second, typical
    • Number of Samples: 1 to 5000
    • Transfer Samples Across IEEE Bus in Binary Mode: 4800 bytes/second, typical
  • Long Integration Mode : 11
    • Measurement time: 850ms (840ms) to 60 seconds in 16.7ms (20ms) steps

General

  • Isolation (Low-Earth): 22VDC max
  • Programming: IEEE-488.2 (SCPI)
  • User-Definable Power-Up States: 5
  • Rear Panel Connector: 8-position quick disconnect terminal block for output(4), sense (2), and DVM (2)
  • Relay Control Jack: 2-channel, sink 150mA max, 15V max (accepts 0.173 in.Bantam-type plug (CS-1003-1))
  • Power Consumption: 200VA max
  • Input Power: 100V–240V AC, 50 or 60Hz (auto detected at power-up)