Hioki PW3198 Power Quality Analyzer
|
Request a Rapid Quote by Email
|
The Hioki PW3198 Power Quality Analyzer can measure all waveforms of power, harmonic, and error events simultaneously. When a problem occurs with the equipment or system on your site, the Hioki PW3198 will help you detect the cause of the problem early and solve it quickly.
Features of the HIoki PW3198 Power Quality Analyzer include:
-
Verify power problems in accordance with the IEC61000-4-30 Class A standard
-
Easy Setup Function with PRESETS
- Just select the measurement course, wiring, and clamps
- Automatic one-step setup based on measurement conditions
-
High Accuracy and continuous gapless recording (V:±0.1% of nominal voltage, A and W:±0.2% rdg. ±0.1% f.s.)
-
CAT IV 600 V - safe enough for incoming power lines
-
Broadband voltage range lets you measure even high-order harmonic components of up to 80 kHz
-
Wide dynamic range from low voltages up to 1300 V (3P4W line-to-line voltage)
-
Maximum 6000 V transient overvoltage up to 700 kHz
-
LAN, USB and SD card interfaces
-
Optional GPS BOX for synchronizing multiple devices
Specifications of the Hioki PW3198 include:
-
Measurement line type: Single-phase 2-wire, Single-phase 3-wire, Three-phase 3-wire or Three-phase 4-wire plus one extra input channel (must be synchronized to reference channel during AC/DC measurement)
-
Voltage ranges:
-
?Voltage measurement: 600.00 V rms
-
Transient measurement 6.0000 kV peak
-
-
Current ranges: 500.00 mA to 5.0000 kA AC (depends on each current sensors)
-
Basic accuracy:
-
Voltage: ±0.1% of nominal voltage
-
Current: ±0.2% rdg. ±0.1% f.s. + current sensor accuracy
-
Active power: ±0.2% rdg. ±0.1% f.s. + current sensor accuracy
-
-
Measurement Functions:
-
Transient overvoltage: 2MHz sampling.
-
Frequency cycle: Calculated as one cycle, 40 to 70Hz
-
RMS voltage/ RMS current refreshed each half-cycle
-
Voltage swell, Voltage dips, Voltage interruption
-
Inrush current
-
Voltage waveform comparison
-
Instantaneous flicker value: As per IEC61000-4-15
-
Frequency: Calculated as 10 or 12 cycles, 40 to 70Hz
-
10-sec frequency: Calculated as the whole-cycle time during the specified 10s period, 40 to 70Hz
-
Voltage waveform peak, Current waveform peak
-
Voltage, Current, Active power, Apparent power, Reactive power, Active energy, Reactive energy, Power factor, Displacement power factor, Voltage unbalance factor, Current unbalance factor (negative-phase, zero-phase)
-
High-order harmonic component (voltage/ current): 2kHz to 80kHz
-
Harmonic/ Harmonic phase angle (voltage/ current), Harmonic power: 0th to 50th oders
-
Harmonic voltage-current phase angle: 1th to 50th orders
-
Total harmonic distortion factor (voltage/ current)
-
Inter harmonic (voltage/ current): 0.5Hz to 49.5Hz
-
K Factor (multiplication factor)
-
IEC Flicker, Δ V10 Flicker
-


Information
