Agilent / HP 4284A LCR Meter, 20 Hz - 1 MHz
|
Request a Rapid Quote by Email
or call us at 760.806.6600 |
Config-02
|
Config-06
|
RENT AGILENT / HP 4284A Precision LCR Meter (call for availability)
The Agilent / HP 4284A Precision LCR Meter is a cost effective solution for material and component measurement. The Agilent / HP 4284A Meter has a wide frequency range and superior test signal performance, which allows this meter to test components to the most commonly used test standards, such as IEC/MIL standards, and under conditions that simulate the intended application. Whether in research and development, production, quality assurance, or incoming inspection, the Agilent / HP 4284A Meter is designed to meet your most rigorous LCR meter test and measurement requirements.
Features and Specifications of the Agilent / HP 4284A LCR Meter include:
The Agilent / HP 4284A Precision LCR Meter is a cost effective solution for material and component measurement. The Agilent / HP 4284A Meter has a wide frequency range and superior test signal performance, which allows this meter to test components to the most commonly used test standards, such as IEC/MIL standards, and under conditions that simulate the intended application. Whether in research and development, production, quality assurance, or incoming inspection, the Agilent / HP 4284A Meter is designed to meet your most rigorous LCR meter test and measurement requirements.
Features and Specifications of the Agilent / HP 4284A LCR Meter include:
- 20 Hz to 1 MHz, with over 8,600 test frequencies
- 0.05% basic accuracy, 6-digit resolution
- Constant V or I test signal level
- List sweep measurement capability
- Parameters Measured: |Z | -q, |Y | -q, R-X, G-B C-D, Q, ESR, G, Rp L-D, Q, ESR, G, Rp Deviation and % deviation
- Measurement Circuit Modes: Series and parallel
- Ranging: Auto and manual
- Trigger: Internal, external, manual, and bus (HP-IB)
- Delay Time: 0 to 60.000s in 1 ms steps
- Measurement Terminals: Four-terminal pair
- Test Cable Length: Standard: 0 and 1 m
- Integration Time: Short, medium, and long
- Averaging: 1 to 256, programmable
- Test Signal: 20 Hz to 1 MHz, 8610 selectable frequencies
- Test Signal Modes
- Normal: Programs selected voltage or current at the measurement terminals open or shorted, respectively, and not at the device under test.
- Constant: Maintains selected voltage or current at the device under test independent of changes in the device's impedance.
- Normal: Programs selected voltage or current at the measurement terminals open or shorted, respectively, and not at the device under test.
- Test Signal Levels (rms)
- Normal: 5mV to 2V, 50µA to 20mA
- Constant: 10mV to 1V, 100µA to 10mA
- Normal: 5mV to 2V, 50µA to 20mA
- DC Bias: 0V, 1.5V and 2V
- Measurement Display Range:
| Measurement Display Range |
Parameter Range: |
| |Z|, R, X |
0.01 mohm to 99.9999 Mohm |
| |Y|, G, B |
0.01 nS to 99.9999 S |
| C |
0.01 fF to 9.9999 F |
| L |
0.01 nH to 99.9999 kH |
| D |
0.000001 to 9.99999 |
| Q |
0.01 to 99999.9 |
| q |
-180.000° to 180.000° |
|
D% |
-999.999% to 999.999% |