Agilent / HP 4284A LCR Meter, 20 Hz - 1 MHz

Price: $7,450.00 (starting at)
See Configurations Below
Model: 4284A
Manufacturer: Agilent / HP

 

Agilent / HP 4284A LCR Meter, 20 Hz - 1 MHz

Request a Rapid Quote by Email

*Required

or call us at  760.806.6600

Available Option Configurations:
 Config-02
  • 001 - Power Amp / DC Bias
  • 006 - 2m/4m Cable length operation
  • 006 - 2m/4m Cable length operation
  Retail Price: $18,743.00 | Our Price: $7,450.00
 Config-06
  • 001 - Power Amp / DC Bias
  • 002 - Bias Current Interface
  Retail Price: $18,589.00 | Our Price: $7,450.00
RENT AGILENT / HP 4284A Precision LCR Meter (call for availability)

The Agilent / HP 4284A Precision LCR Meter is a cost effective solution for material and component measurement. The Agilent / HP 4284A Meter has a wide frequency range and superior test signal performance, which allows this meter to test components to the most commonly used test standards, such as IEC/MIL standards, and under conditions that simulate the intended application. Whether in research and development, production, quality assurance, or incoming inspection, the Agilent / HP 4284A Meter is designed to meet your most rigorous LCR meter test and measurement requirements.

Features and Specifications of the Agilent / HP 4284A LCR Meter include:
  • 20 Hz to 1 MHz, with over 8,600 test frequencies
  • 0.05% basic accuracy, 6-digit resolution
  • Constant V or I test signal level
  • List sweep measurement capability
  • Parameters Measured: |Z | -q, |Y | -q, R-X, G-B C-D, Q, ESR, G, Rp L-D, Q, ESR, G, Rp Deviation and % deviation
  • Measurement Circuit Modes: Series and parallel
  • Ranging: Auto and manual
  • Trigger: Internal, external, manual, and bus (HP-IB)
  • Delay Time: 0 to 60.000s in 1 ms steps
  • Measurement Terminals: Four-terminal pair
  • Test Cable Length: Standard: 0 and 1 m
  • Integration Time: Short, medium, and long
  • Averaging: 1 to 256, programmable
  • Test Signal: 20 Hz to 1 MHz, 8610 selectable frequencies
  • Test Signal Modes
    • Normal: Programs selected voltage or current at the measurement terminals open or shorted, respectively, and not at the device under test.
    • Constant: Maintains selected voltage or current at the device under test independent of changes in the device's impedance.
  • Test Signal Levels (rms)
    • Normal: 5mV to 2V, 50µA to 20mA
    • Constant: 10mV to 1V, 100µA to 10mA
  • DC Bias: 0V, 1.5V and 2V
  • Measurement Display Range: 

Measurement Display Range
Parameter Range:
|Z|, R, X
0.01 mohm to 99.9999 Mohm
|Y|, G, B
0.01 nS to 99.9999 S
C
0.01 fF to 9.9999 F
L
0.01 nH to 99.9999 kH
D
0.000001 to 9.99999
Q
0.01 to 99999.9
q
-180.000° to 180.000°

D%

-999.999% to 999.999%